When inspecting the safety of incinerator, the following factors should be considered.

2fa25692883803a66704a33aa36e16f

1. Furnace body inspection

Check the exterior of the incinerator for signs of damage, corrosion, or gas leakage, 

ensure that the furnace structure is intact and there are no cracks or deformation.

53d612dd644bb1b8951ddc88a76cbdb

2. Combustion system

Check the burner and combustion chamber to make sure they are clean and free of residue 

and well connected. Check whether the burner nozzle is blocked and make sure combustion 

flow is normal, and make sure the flame looks stable and blue, with no noticeable yellow flame.


90a0f85d6962b6b45e1721f26432d1b

3. Exhaust system

Check chimneys and flues for carbon deposits, clogs or breakage. ensure that the flue 

gas discharge is smooth and will not cause pollution to the surrounding environment.

2a279b48077c7f7d7c6fcfd701a0cc3

4. Protective device

Check whether the safety valve, temperature sensor, pressure control device and other 

protective devices of the incinerator are working properly, so that the pressure, temperature 

and other parameters in the furnace can be controlled within the safe range.

53d612dd644bb1b8951ddc88a76cbdb

5. Fuel supply

Check the fuel supply system, including fuel storage tanks, gas supply lines, power lines, etc. 

Ensure a stable and reliable fuel supply with no leaks or ground fault.

7d238eb9cb34249f66a6170ffde56fc7d238eb9cb34249f66a6170ffde56fc

6. Cooling system

Check the cooling system of the incinerator to ensure the normal operation of the water tank, 

water pump, cooling pipe, etc. It can effectively dissipate heat and prevent overheating from causing safety accidents.

303dfe6ade44f96194448ad3ce81652

7. Control system

Check the automatic control system or operation panel of the incinerator to ensure that it is 

functioning properly, can control the parameters in the furnace accurately, and has an alarm function.

732f2bcee1adf39e3bdbe424952cad8

8. Safety measures: 

Check the safety facilities around the incinerator, such as firefighting apparatus, emergency stop buttons, 

safety signs, etc. Make sure these facilities are available and easy to operate.


  It should be noted that the content above is for reference only, and the specific safety inspection 

content may vary depending on the type, size and use of the incinerator. It is better to carry out 

specific safety checks according to the operating instructions or relevant specifications of the 

incinerator. In addition, if you are not familiar with the safety check or have any problems, it is

 recommended to consult a professional or relevant department for guidance.


ABOUT US

AIR CLEAN

AIR FILTER

CONTACT US

   086-15261025665
Leave a Message
© 2018-2028 Suzhou Industrial Park Santy Cleaning Equipment Co., LTD
We use cookies to enable all functionalities for best performance during your visit and to improve our services by giving us some insight into how the website is being used. Continued use of our website without having changed your browser settings confirms your acceptance of these cookies. For details please see our privacy policy.
×